Ground-up commercial fire alarm systems for new construction across Greater Houston — engineered, installed, coordinated with the general contractor and every trade, and inspected through final AHJ acceptance by vetted, licensed contractors.
You’re matched with a vetted, licensed contractor from our network to deliver the fire alarm system for your ground-up commercial, industrial, or institutional project throughout the Greater Houston area. From the engineered design and permit submittal through rough-in, device installation, programming, and the witnessed acceptance test that clears your Certificate of Occupancy, the entire fire alarm scope is managed and coordinated with your general contractor, electrical contractor, and sprinkler contractor. The result is a system that satisfies NFPA 72, the International Building Code, and your local Authority Having Jurisdiction — installed on the construction schedule instead of holding it up. For an existing or occupied building rather than a ground-up build, see Installation; for standalone engineered drawings and a permit plan set, see Design & Engineering.
General contractor coordination — the fire alarm contractor works from the construction schedule, attends coordination meetings, and sequences rough-in and trim-out around the other trades
Design through acceptance under one contract — engineered drawings, permit submittal, installation, programming, and the final witnessed test handled as a single continuous scope
Trade interconnection managed — sprinkler waterflow and tamper supervision, elevator recall, HVAC shutdown, and door-holder release coordinated with the electrical, mechanical, and sprinkler contractors
Built to pass the CO inspection — the system is engineered and installed so the witnessed AHJ acceptance test clears the fire alarm portion of your Certificate of Occupancy on time
Phased and multi-building delivery — fire alarm work sequenced to match phased occupancy, temporary COs, and building-by-building acceptance on larger developments
Turnover documents and ongoing support — record drawings, certificate of completion, and warranty at closeout, plus a network for the inspection, monitoring, and service the building needs from day one
New construction fire alarm systems are delivered for a wide range of commercial and institutional projects across Greater Houston, including:
Every new construction fire alarm system is designed and installed to comply with NFPA 72 (National Fire Alarm and Signaling Code), the International Building Code (IBC), the International Fire Code (IFC), and NFPA 101 (Life Safety Code), along with the local amendments enforced by the Authority Having Jurisdiction. On a new build the fire alarm scope is closely tied to the building’s occupancy classification, egress design, sprinkler system, and mechanical systems, so the contractor coordinates the interconnections during design and verifies them during the witnessed acceptance test. That final test, documented and signed off by the AHJ, is what clears the fire alarm portion of your Certificate of Occupancy.
You’re matched with contractors who deliver new construction fire alarm systems across all nine regions of Greater Houston, plus Galveston. Each jurisdiction has its own permit process, acceptance-testing procedure, and Certificate of Occupancy requirements, and that coordination is handled as part of every project.
As early as possible — ideally during design or preconstruction. Bringing the fire alarm contractor in before the walls close lets the engineered drawings be submitted for permit on schedule and coordinates the rough-in with the electrical, sprinkler, and low-voltage trades. Waiting until late in the build usually means change orders and schedule pressure at the worst time.
It depends on the project delivery method. On a plan-and-spec job the engineer of record provides the design and the contractor installs to it; on a design-build or deferred-submittal job the fire alarm contractor engineers the system and submits the drawings themselves. Either way, the contractor you're matched with can produce or work from the engineered drawings your permit requires.
The fire alarm system supervises the sprinkler system through waterflow and tamper switches and initiates the required alarm and supervisory signals, and it connects to a UL-listed central station for 24/7 monitoring. That coordination is planned during design and verified during acceptance testing so every interconnected system is confirmed working before occupancy.
Before a Certificate of Occupancy is issued, the fire alarm system must pass a witnessed acceptance test with the Authority Having Jurisdiction, and the contractor must provide the required documentation — record drawings, the certificate of completion, battery and device records, and the sequence of operations. The contractor coordinates that final inspection so the fire alarm sign-off doesn't hold up your CO.
Yes. Large developments are commonly delivered in phases, and the fire alarm work is sequenced to match — supporting phased occupancy, temporary certificates of occupancy, and building-by-building acceptance testing. The contractor you're matched with coordinates the fire alarm schedule with the overall construction phasing plan.